Our MProbe system has many different accessories that can be added to existing system. Some of them are included in the standard configurations(of particular systems), others are optional. Practically all the accessories can be used in general purpose optical lab.
Accessories are divided in several groups:
1. Sample stages. A list of available single point stages for reflectance, transmittance and fluorescent measurement with fiberoptics
2. Reflectance probes. A list of Fiberoptics Reflectance probes. The probes use silica 400 um core multimode fibers, have stainless steel monocoil jacket with soft silicon cover – this makes fiberoptics components strong, durable and flexible at the same time. Termination is SMA905 on all sides.
3. Fiberoptics patch and bifurcated cables. Patch cables use silica 400 um core multimode fiber and have stainless steel monocoil and soft silicon jacket. SMA 905 terminated.
4.Calibration and test samples
5. Spare parts
6. Microscope lenses
All items can be purchased directly online with payment processed via Paypal. Shipping charge will be added at the checkout. Most items are shipped within 2 business days (out of stock items may have 2-3 weeks lead time).
If you need multiple items, you maybe eligible for a discount – please contact us to receive a custom quotation.
Sample holders and focusing lenses for Reflectance/Fluorescence and Transmittance measurement | |||
SH200A stage | Universal Reflectance stage (single-point measurement) with focusing lens and fine height adjustment mechanism. Suitable for measurement samples with different substrate thickness (using the same calibration sample). SMA905 connector for reflectance. FD SMA905 terminated adapter is included for dace-down/inverted configuration measurement. Holds samples up to 200 x200 mm. Focusing lens (-FLVis or -FLUVVis) is required but is not included | US$1840 | |
TOSH-Vis transmittance kit | Transmittance measurement option for SH200A stage. Includes 4 stainless steel posts and 2 fiberoptics cable P400Vis. Working wavelength range: 350nm -2200nm | US$650 | |
TOSH-UVVis transmittance kit | Transmittance measurement option for SH200A stage. Includes 4 stainless steel posts and 2 fiberoptics cable P400UVVis. Working wavelength range: 200nm -1100nm | US$650 | |
TOSH-UVNIR transmittance kit | Transmittance measurement option for SH200A stage. Includes 4 stainless steel posts and mixed 2 fiberoptics cable P400Vis.Working wavelength range: 350nm -2200nm | US$850 | |
SS100 stage | Reflectance stage (single-point measurement) with the probe holder and SMA905 connector. Holds samples up to 120mm diameter). Focusing lens is required and is not included | US$450 | |
SS300 stage | Reflectance stage (single-point measurement) with the probe holder and SMA905 connector. Holds samples up to 300x300mm | US$570 | |
FD150 stage | Universal Reflectance stage (single-point measurement) for face-down/inverted measurement configuration. Includes SMA905 adapter for reflectance probe. Suitable for foils, flexible polymer films/sheets, thick or non-standard samples. Can be used for any sample. Holds samples up to 150 x 150mm (larger samples can be accomodated) | US$450 | |
T0150Vis transmittance kit | Transmission fixture added to FD150 stage. Includes: collimator lens, fiber holder with SMA905 connector, stainless steel post, 2 fiberoptics Vis cables (P400Vis). Transmittance measurement of samples up to 300mm diameter. Working wavelength range: 350nm -2200nm | US$850 | |
T0150UVVis transmittance kit | Transmission fixture added to FD150 stage. Includes: collimator lens, fiber holder with SMA905 connector, stainless steel post, 2 fiberoptics Vis cables (P400UVVis). Transmittance measurement of samples up to 300mm diameter. Working wavelength range: 200nm -1100nm | US$850 | |
T0150UVNIR transmittance kit | Transmission fixture added to FD150 stage. Includes: collimator lens, fiber holder with SMA905 connector, stainless steel post, 2 fiberoptics Vis cables (P400UVVisNIR). Transmittance measurement of samples up to 300mm diameter.Working wavelength range: 200nm -2200nm | US$1100 | |
FLVis achromatic lens | Focusing lens (Achromatic visible range) to reduce reflectance measurement spot size (<400um spot with RP400-VisNIR probe) in the visible-NIR range. Attached to reflectance probe holder(UNF3/8-24 connector thread). Wavelength range: 350-1000nm Compatibility: can be used with SS100, SS300 and SH200A stages | US$450 | |
FLUV lens | Focusing lens (UV Fused silica) to reduce reflectance measurement spot size (< 400um spot with RP400-UVVis probe) in the UV-Vis range.. Attached to reflectance probe holder (UNF3/8-24 connector thread). Wavelength range: 200-2200nm (fixed position:200-1000nm or 900nm-2200nm range)Compatibility: can be used with SS100, SS300 and SH200A stages | US$450 | |
FLUVNIR achromatic lens | Achromatic triplet lens (CaF2/Fused Silica/CaF2) reduces the spot size to ~60um in UV-NIR range. Attached to reflectance probe holder (UNF3/8-24 connector thread). Can be used with SS100 or SS300 stage | US$1250 | |
Reflectance/Fluorescence Probes (Fiberoptics) 6 illumination fiber around 1 “read” fiber (12 illumination fiber around 2 “read” fibers in the mixed assemblies) Armored (stainless steel monocoil) with silicon jacket. Total length: 2m. Termination: SMA connectors all ends. Length 2m total. All probes are tested and compatible with MProbe measurement systems. | |||
RP400-VisNIR – reflectance probe | Reflectance probe Vis NIR, 400um fiber core, Wavelength range: 400nm-2500nm | US$575 | |
RP400-UVVis – reflectance probe | Reflectance probe UVVis, 400um fiber core, 200-1100nm. Solarization resistant fibers. | US$650 | |
RP400-UVVisNIR-mixed reflectance probe | Reflectance probe UVVisNIR, 400um fiber core, 200-2200nm. Mixed VisNIR and UV (solarization resistant) fibers in one assembly to cover extended wavelength range | US$1450 | |
Fiberoptics patch and bifurcated cables Single Strand Multimode Fiberoptics (armored with steel monocoil,jacketed) | |||
P400Vis cable | 400um fiberoptics cable, 2 m long, 400-2500nm transmission | US$250 | |
BF400Vis bifurcated cable | 400um bifurcated fiberoptics cable, 0.3m long, 400-2500nm transmission. 2 fiber in the common end | US$270 | |
BF400Vis6 bifurcated cable | 400um bifurcated fiberoptics cable, 2 m long, 400-2500nm transmission. 6 fibers at the common end | US$650 | |
P400UVSR cable | 400um fiberoptics cable, 2 m long, 200-1100nm transmission | US$250 | |
BP400UVSR bifurcated cable | 400um bifurcated fiberoptics cable, 0.3m long, 200-1100nm transmission. 2 fiber in the common end | US$300 | |
Calibration/test samples | |||
Si wafer | 2″ (50mm) Si wafer SSP (single side polished) for reflectance calibration in UVVis range | US$80 | |
Al mirror | 0.5″ (12.7mm) Al mirror (first surface) for calibration/test in NIR and wide spectral range UVVisIR | US$110 | |
Quartz plate | 2″x2″ (50x50mm) Ultra UV grade Fused silica plate, 0.25″ ( 6mm) thick, SSP. For calibration in a wide spectral range(UVVisNIR) in case of low reflective samples | US$85 | |
Quartz slide | 30mm x 17mm, 1mm thick, Ultra UV grade Fused silica slide, double polished. For transmittance test. Also, used for calibration in case of backside reflective sample of similar thickness. 200nm -22000nm wavelength range | US$18 | |
200nm Oxide test wafer | 200nm oxide/Si wafer used to test the measurement UV and Vis MProbe system. Wafer is calibrated and exact thickness is listed | US$85 | |
Black pad/absorber | 2″x2″ (50x50mm) back absorber pad for calibration (dark current measurement) | US$10 | |
Calibration kit for UVVis and Vis systems | Incluides: 2″ (50mm) Si wafer, 2″(50mm), 200nm oxide/Si wafer, black absorber pad | US$160 | |
Calibration kit for NIR, VisNIR systems | Includes: 0.5″ (12.7mm) Al mirror, Quartz Plate and black absorber pad | US$200 | |
Universal test wafer with 5 oxides | 4″ wafer with 5 different oxide areas:100nm, 200nm,300nm,400nm,500nm and bare Si area. Oxide thicknesses are calibrated. Can be used for testing measurement of UVVis/Vis system | US$1150 | |
Spare parts | |||
5W bulb assembly | 5W bulb assembly with reflector and lens. Used in all MProbeVis/VisNIR/NIR/UVVISNIR-RT | US$80 | |
20W bulb assembly | 20W bulb assembly with reflector and lens. Used in MProbeUVVisSR | US$95 | |
30W Deuterium lamp assembly | 30W Deuterium lamp assembly. Used in MProbeUVVisSR | US$850 | |
Spare lamps set for MProbe UVVisSR | A set of 20W TH lamp and 30W Deuterium lamp assemblies for MProbe UvVisSR system | US$945 | |
Miscroscope lenses for MProbe MSP system and other optical components | |||
Quartz collimator assembly | UV Fused silica collimator assembly. Black anodized Al body with SMA905 connector and UNF3/8-24 external. Beam diameter ~ 5mm. Divergence < 2deg Used in transmittance options. Wavelength range: 200-22000nm | US$95 | |
10X APO Objective | Infinity corrected, 10x,long distance visible objective with 95mm parfocal length. Uses M26x0.705 thread. Working distance (WD) is 34mm. Resolving power – 1um. NA – 0.28. Used in MProbeMSP system | US$550 | |
20X APO Objective | Infinity corrected, 20x, long working distance visible objective with 95mm parfocal length. Uses M26x0.705 thread. Working distance (WD) is 31mm. Resolving power – 1um. NA – 0.29. Used in MProbeMSP system | US$1150 | |
50X APO Objective | Infinity corrected, 50x, long working distance visible objective with 95mm parfocal length. Uses M26x0.705 thread. Working distance (WD) is 21mm. Resolving power – 0.7um. NA – 0.42. Used in MProbeMSP system | US$1250 | |
8x Achromatic UVVisNIR Objective | Infinity corrected, 8x, long working distance achromatic objective with 95mm parfocal length. Uses M26x0.705 thread. Working distance (WD) is 30mm. Resolving power – 20um. NA – 0.22. Working wavelength range:200-2200nm. Used in MProbeMSP system | US$1550 | |
A set of 4 visible Objective | includes 4 Visible,Infinity corrected,long working distance objectives with 95mm parfocal length. All use M26x0.705 thread. Include 2x, 10x, 20x and 50cx objective | US$3200 |