Accessories: Online Store


Our MProbe system has many different accessories that can be added to existing system. Some of them are included in the standard configurations(of particular systems), others are optional. Practically all the accessories can be used in general purpose optical lab.

Accessories are divided in several groups:
1. Sample stages. A list of available single point stages for reflectance, transmittance and fluorescent measurement with fiberoptics

2. Reflectance probes. A list of Fiberoptics Reflectance probes. The probes use silica 400 um core multimode fibers, have stainless steel monocoil  jacket with soft silicon cover – this makes fiberoptics  components strong, durable and flexible at the same time. Termination is SMA905 on all sides.

3. Fiberoptics patch and bifurcated cables. Patch cables use silica 400 um core multimode fiber and have stainless steel monocoil and soft silicon jacket. SMA 905 terminated.

4.Calibration and test samples

5. Spare parts

6. Microscope lenses

All items can be purchased directly online with payment processed via Paypal. Shipping charge will be added at the checkout. Most items are shipped within 2 business days (out of stock items may have 2-3 weeks lead time).
If you need multiple items, you maybe eligible for a discount – please contact us to receive a custom quotation.

Sample holders and focusing lenses

for Reflectance/Fluorescence and Transmittance measurement

SH200A stage Universal Reflectance stage (single-point measurement) with focusing lens and fine  height adjustment mechanism. Suitable for measurement samples with different substrate thickness (using the same calibration sample).  SMA905 connector for reflectance. FD SMA905 terminated adapter is included for dace-down/inverted configuration measurement. Holds samples up to 200 x200 mm.  Focusing lens (-FLVis or -FLUVVis) is required but is not includedUS$1840



TOSH-Vis transmittance kitTransmittance measurement option for SH200A stage. Includes 4 stainless steel posts and 2 fiberoptics cable P400Vis. Working wavelength range: 350nm -2200nmUS$650


TOSH-UVVis transmittance kitTransmittance measurement option for SH200A stage. Includes 4 stainless steel posts and 2 fiberoptics cable P400UVVis. Working wavelength range: 200nm -1100nmUS$650


TOSH-UVNIR transmittance kitTransmittance measurement option for SH200A stage. Includes 4 stainless steel posts and mixed 2 fiberoptics cable P400Vis.Working wavelength range: 350nm -2200nmUS$850


SS100 stageReflectance stage (single-point measurement) with the probe holder and SMA905 connector. Holds samples  up to 120mm diameter). Focusing lens is required and is not includedUS$450


SS300 stageReflectance stage (single-point measurement) with the probe holder and SMA905 connector. Holds samples up to 300x300mmUS$570


FD150 stageUniversal Reflectance stage (single-point measurement) for face-down/inverted measurement configuration. Includes SMA905 adapter for reflectance probe. Suitable for foils, flexible polymer films/sheets, thick or non-standard samples. Can be used for any sample. Holds samples up to 150 x 150mm (larger samples can be accomodated)US$450


T0150Vis transmittance kitTransmission fixture added to FD150 stage. Includes: collimator lens, fiber holder with SMA905 connector, stainless steel post, 2 fiberoptics Vis cables (P400Vis). Transmittance measurement of samples up to 300mm diameter. Working wavelength range: 350nm -2200nmUS$850


T0150UVVis transmittance kitTransmission fixture added to FD150 stage. Includes: collimator lens, fiber holder with SMA905 connector, stainless steel post, 2 fiberoptics Vis cables (P400UVVis). Transmittance measurement of samples up to 300mm diameter. Working wavelength range: 200nm -1100nmUS$850


T0150UVNIR transmittance kitTransmission fixture added to FD150 stage. Includes: collimator lens, fiber holder with SMA905 connector, stainless steel post, 2 fiberoptics Vis cables (P400UVVisNIR). Transmittance measurement of samples up to 300mm diameter.Working wavelength range: 200nm -2200nmUS$1100


FLVis achromatic lens Focusing lens (Achromatic visible range) to reduce reflectance measurement spot size (<400um spot with RP400-VisNIR probe) in the visible-NIR range. Attached to reflectance probe holder(UNF3/8-24 connector thread).  Wavelength range: 350-1000nm Compatibility: can be used with SS100, SS300  and SH200A stagesUS$450


FLUV lensFocusing lens (UV Fused silica)  to reduce reflectance measurement spot size (< 400um spot with RP400-UVVis probe) in the UV-Vis range.. Attached to reflectance probe holder (UNF3/8-24 connector thread). Wavelength range: 200-2200nm (fixed position:200-1000nm or 900nm-2200nm range)Compatibility: can be used with SS100, SS300  and SH200A stagesUS$450


FLUVNIR achromatic lensAchromatic triplet lens (CaF2/Fused Silica/CaF2) reduces the spot size to ~60um in UV-NIR range. Attached to reflectance probe holder (UNF3/8-24 connector thread). Can be used with SS100 or SS300 stageUS$1250


Reflectance/Fluorescence Probes (Fiberoptics)

6 illumination fiber around 1 “read” fiber (12 illumination fiber around 2 “read” fibers in the mixed assemblies)

Armored (stainless steel monocoil) with  silicon jacket. Total length: 2m. Termination:  SMA connectors all ends. Length 2m total. All probes are tested and compatible with MProbe measurement systems.

RP400-VisNIR – reflectance probeReflectance probe Vis NIR, 400um fiber core, Wavelength range: 400nm-2500nmUS$575


RP400-UVVis – reflectance probeReflectance probe UVVis, 400um fiber core, 200-1100nm. Solarization resistant fibers.US$650


RP400-UVVisNIR-mixed reflectance probeReflectance probe UVVisNIR, 400um fiber core, 200-2200nm. Mixed VisNIR and UV (solarization resistant) fibers in one assembly to cover extended wavelength rangeUS$1450


Fiberoptics patch  and bifurcated cables

Single Strand Multimode Fiberoptics (armored with steel monocoil,jacketed)
terminated with SMA connectors(all sides)

P400Vis  cable400um fiberoptics cable, 2 m long, 400-2500nm transmissionUS$250


BF400Vis  bifurcated cable400um bifurcated fiberoptics cable, 0.3m long, 400-2500nm transmission.  2 fiber in the common endUS$270


BF400Vis6  bifurcated cable400um bifurcated fiberoptics cable, 2 m long, 400-2500nm transmission. 6 fibers at the common endUS$650


P400UVSR cable400um fiberoptics cable, 2 m long, 200-1100nm transmissionUS$250


BP400UVSR bifurcated cable400um bifurcated fiberoptics cable, 0.3m long, 200-1100nm transmission.  2 fiber in the common endUS$300


Calibration/test samples

Si wafer2″ (50mm) Si wafer SSP (single side polished) for reflectance calibration in UVVis rangeUS$80


Al mirror0.5″ (12.7mm) Al mirror (first surface) for calibration/test in NIR and wide spectral range UVVisIR  US$110


Quartz plate2″x2″ (50x50mm) Ultra  UV grade Fused silica plate, 0.25″ ( 6mm) thick, SSP. For calibration in a wide spectral range(UVVisNIR) in case of low reflective samplesUS$85


Quartz slide30mm x 17mm, 1mm thick, Ultra UV grade Fused silica slide, double polished. For transmittance test. Also, used for calibration in case of backside reflective sample of similar thickness. 200nm -22000nm wavelength rangeUS$18


200nm Oxide test wafer200nm oxide/Si wafer used to test the measurement UV and Vis MProbe system. Wafer is calibrated and exact thickness is listedUS$85


Black pad/absorber2″x2″ (50x50mm)  back absorber pad for calibration (dark current measurement)US$10


Calibration kit for UVVis and Vis systemsIncluides: 2″ (50mm) Si wafer, 2″(50mm), 200nm oxide/Si wafer, black absorber pad  US$160


Calibration kit for NIR, VisNIR systemsIncludes: 0.5″ (12.7mm) Al mirror, Quartz Plate and black absorber pad US$200


Universal test wafer with 5 oxides4″ wafer with 5 different oxide areas:100nm, 200nm,300nm,400nm,500nm and bare Si area. Oxide thicknesses are calibrated. Can be used for testing measurement of UVVis/Vis systemUS$1150


Spare parts 
5W bulb assembly5W bulb assembly with reflector and lens. Used in all MProbeVis/VisNIR/NIR/UVVISNIR-RTUS$80


20W bulb assembly20W bulb assembly with reflector and lens. Used in  MProbeUVVisSRUS$95


30W Deuterium lamp assembly30W Deuterium lamp assembly. Used in  MProbeUVVisSRUS$850


Spare lamps set for MProbe UVVisSR A set of 20W TH lamp and 30W Deuterium lamp assemblies for MProbe UvVisSR systemUS$945


Miscroscope lenses for MProbe MSP system and other optical components
Quartz collimator assemblyUV Fused silica collimator assembly. Black anodized Al body with SMA905 connector and UNF3/8-24 external. Beam diameter ~ 5mm. Divergence < 2deg Used in transmittance options. Wavelength range: 200-22000nmUS$95


10X APO Objective Infinity corrected, 10x,long distance visible objective with 95mm parfocal length. Uses M26x0.705 thread. Working distance (WD) is 34mm. Resolving power – 1um. NA – 0.28. Used in MProbeMSP systemUS$550


20X APO Objective Infinity corrected, 20x, long working distance visible objective with 95mm parfocal length. Uses M26x0.705 thread. Working distance (WD) is 31mm. Resolving power – 1um. NA – 0.29. Used in MProbeMSP systemUS$1150


50X APO Objective Infinity corrected, 50x, long working distance visible objective with 95mm parfocal length. Uses M26x0.705 thread. Working distance (WD) is 21mm. Resolving power – 0.7um. NA – 0.42. Used in MProbeMSP systemUS$1250


8x Achromatic UVVisNIR Objective Infinity corrected, 8x, long working distance achromatic objective with 95mm parfocal length. Uses M26x0.705 thread. Working distance (WD) is 30mm. Resolving power – 20um. NA – 0.22. Working wavelength range:200-2200nm. Used in MProbeMSP systemUS$1550


A set of 4 visible Objective includes 4 Visible,Infinity corrected,long working distance objectives with 95mm parfocal length. All use M26x0.705 thread. Include 2x, 10x, 20x and 50cx objectiveUS$3200